e-Learning in electrical engineering

Search | Navigation principles
Electromagnetic conversion Rotating field machines Synchronous machine Asynchronous machine MCQs

Measurement of the parameters

Within this virtual laboratory will be presented the methods to determine the parameters of the equivalent diagram of the asynchronous machine

    • stator phase resistance, R1
    • rotor phase resistance, reported to the stator, R¢2
    • magnetizing inductance, Lm
    • stator phase leakage inductance, L1s or Lss
    • rotor phase leakage inductance, reported to the stator, L¢2s or Lrs

and of the mechanical parameters

    • rotor moment of inertia, J
    • viscous frictions coefficient kv
    • dry friction torque Tf

necessary both for the simulation of the drive systems and for tuning the parameters of the control diagrams.